Irreversible membrane scaling caused by silica remains a severe problem in many reverse osmo-sis plants. The engineering task is to find out the appropriate anti-scalant agent and its optimal dosage. Because suitable test methods are missing, a new membrane-based test method was de-veloped. The fully automatically controlled test set-up and the test procedure are described. The effectiveness of 13 anti-scalants for silica was measured at different pH-values between 7.6 and 9.0 and with silica concentrations from 120 mg/l to 275 mg/L. The results show that two of the anti-scalants investigated in this paper have a significant anti-scaling effect for silica.
This presentation is available to AMTA Members only.
Speaker
- Christian zum Kolk / Gerd Braun / Jolanthe Jaworski
Company
- BK Giulini GmbH / Cologne University of Appliced Sciences
Event
- AWWA/AMTA Membrane Technology Conference, Glendale, AZ
Session
- AWWA/AMTA Membrane Technology Conference
Date
- 02/27/12
Media
Keywords
- Anti-Scalants, Silica-Scaling, Reverse Osmosis
Reference
- 9658-DP1058